ORing Switch Model |
IAP-420 |
IAP-420+ |
Physical Ports |
|
10/100Base-T(X) Ports in RJ45 Auto MDI/MDIX |
2 |
PoE P.D. Port |
— |
Present at ETH
Fully compliant with IEEE 802.3af Power Device specification
Over load & short circuit protection
Isolation Voltage: 1000 VDC min.
Isolation Resistance : 108 ohms min |
WLAN Interface |
|
Operating Mode |
AP/Client/Bridge/AP-Client |
Antenna and Connector |
1 x External reverse SMA-type antenna connector |
Radio Frequency Type |
DSSS, OFDM |
Modulation |
IEEE802.11b: CCK, DQPSK, DBPSK
IEEE802.11g/n: OFDM with BPSK, QPSK, 16QAM, 64QAM |
Frequency Band |
America / FCC:
2.412~2.462 GHz (11 channels )
Europe CE / ETSI:
2.412~2.472 GHz ( 13 channels ) |
Transmission Rate |
802.11b: 1/2/5.5/11 Mbps
802.11g: 6/9/12/18/24/36/48/54 Mbps
802.11n(40MHz): UP to 150 Mbps |
Transmit Power |
802.11b: 19dBm ±1.5dBm
802.11g: 17dBm ±1.5dBm
802.11n(2.4G@20MHz): 16.5dBm ±1.5dBm
802.11n(2.4G@40MHz): 14.5dBm ±1.5dBm |
Receiver Sensitivity |
802.11b: -90dBm ±2dBm@1Mbps
802.11g: -72dBm ±2dBm@54Mbps
802.11n(2.4G@40MHz,MCS7): -68dBm ±2dBm |
Encryption Security |
WEP: (64-bit, 128-bit key supported)
WPA/WPA2:802.11i (WEP and AES encryption)
WPA-PSK (256-bit key pre-shared key supported)
802.1X Authentication supported
TKIP encryption |
Wireless Security |
SSID broadcast disable and enable |
Protocol Support |
|
Protocol |
ARP,BOOTP, DHCP, DNS, HTTP, IP, ICMP, SNTP, TCP, UDP, 802.1X, SNMP, STP |
LED Indicators |
|
Power Indicator |
LED x 3, PWR 1, 2, (PoE):
Green On: Power is on and functioning Normally. |
10/100Base-T(X) RJ45 Port Indicator |
LED x 2 , Green for port Link/Act at 100Mbps. |
WLAN LEDs |
WLAN Link /ACT: Green: Blinking |
Power |
|
Redundant Input Power |
Dual DC inputs. 12~48VDC on 4-pin terminal block |
Power Consumption (Typ.) |
4 Watts |
Overload Current Protection |
Present |
Reverse Polarity Protection |
Present |
Physical Characteristics |
|
Enclosure |
IP-30 |
Dimensions (W x D x H) |
41(W)x81(D)x95(H) mm |
Weight (g) |
292 g |
297 g |
Environmental |
|
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Operating Temperature |
-10 to 60°C(14 to 140°F) |
Operating Humidity |
5% to 95% Non-condensing |
Regulatory Approvals |
|
EMI |
FCC Part 15, CISPR (EN55022) class A |
EMS |
IEC61000-4-2 (ESD), IEC61000-4-3 (RS), IEC61000-4-4 (EFT), IEC61000-4-5 (Surge), IEC61000-4-6 (CS), IEC61000-4-8, IEC61000-4-11 |
Shock |
IEC60068-2-27 |
Free Fall |
IEC60068-2-31 |
Vibration |
IEC60068-2-6 |
Safety |
EN60950-1 |