DRP048V240W1BN — 240W, 48 VDC output, -40 ~ +75 °C.

240 Вт на DIN-рейку 24 В постоянного тока / 10А с универсальным входом от 100 до 240 В переменного тока, расширенный тип, -25 ~ 80 ° C

Спецификация

Model Name DRP024V240W1BN DRP048V240W1BN
Physical Ports
Output DC Voltage 24V 48V
Rated Current 10A 5A
Current Range 0 ~ 10A 0 ~ 5A
Rated Power 240 watts 240 watts
Peak Current 15A 7.5A
Peak Power 360W (5sec.) 360W (5sec.)
Ripple & Noise (max.) 150mVp-p 200mVp-p
Voltage ADJ. Range 24 ~ 28V 48 ~ 56V
Voltage Tolerance ±2.0% ±1.0%
Line Regulation ±0.5% ±0.5%
Load Regulation ±1.0% ±1.0%
Setup, Rise Time 1000ms, 100ms at full load 1000ms, 200ms at full load
Hold Up Time (Typ.) 20ms/115VAC & 230VAC at full load 20ms/115VAC & 230VAC at full load
iutput Voltage Range 85 ~ 264VAC 120 ~ 375VDC 85 ~ 264VAC 120 ~ 375VDC
Frequency Range 47 ~ 63Hz 47 ~ 63Hz
Efficiency (Typ.) 90% 90%
AC Current (Typ.) <2.5A/115VAC <1.3A/230VAC <2.5A/115VAC <1.3A/230VAC
Inrush Current (Typ.) 35A/230VAC & 115VAC 35A/230VAC & 115VAC
Leakage Current <1mA/240VAC <1mA/240VAC
Protection Overload For more than 150% rated output power, will enter Hicc-up mode with auto-recovery
Over Voltage 32V 57V
Protection type : Hicc-up mode with auto-recovery
Over Temperature 80oC (Surround air temperature with full load)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
Short Circuit When short circuit occurred, enter Hicc-up mode with auto-recovery
Environment Working Temp. -25 ~ +80oC (with -40oC cold start. Also refer to output load derating curve)
Working Humidity 5 ~ 95% RH (non-condensing)
Storage Temp., Humidity -40 ~ 85oC, 10 ~ 95% RH
Working Altitude 0 ~ 2,500m
Shock IEC60068-2-27, 30G (300m/S²) for a duration of 18ms
Vibration IEC60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak);
60 min per axis for all X, Y, Z direction
Safety & EMC Withstand Voltage I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC
Safety Standards UL/cUL508, UL/cUL60950-1, EN60950-1, CB scheme
EMI conduction & Radiation Compliance to EN55022 (CISPR22) and FCC Class B
Harmonic Current Compliance to EN61000-3-2,-3
EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11,12, EN55024, EN61000-6-2
Others MTBF 500Khrs min. Telcordia SR-332 (25oC)
Dimension 85*121*124.1mm (W*H*D)
Packing 1.1Kg 0.96Kg
Note All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25oC of ambient temperature.